Training Library
Our off the shelf content library covers a wide range of medical devices, including diagnostic equipment, imaging machines, and surgical instruments and we are adding new devices all the time.
Philips IntelliVue MX800 Patient Monitor
Preventative Maintenance
Performance Assurance Test procedures for the Philips IntelliVue MX800 using a Fluke Prosim 8.
LIFEPAK 20e Defibrillator
Preventative Maintenance Inspection
Full preventative maintenance procedures for a Physio-Control LifePak 20e defibrillator using a Fluke Impulse 7000DP analyzer.
GE MAC 5500 ECG
Lead Failure
Determine if a lead or acquisition box is faulty on a Mac 5500 ECG machine using the Fluke Prosim 8 patient simulator.
Ohmeda Suction Regulator
Device Rebuild
Use a Pronk SimCube manometer to test the suction on a wall mounted suction regulator. Disassemble the device and replace all filters, gaskets, and O-rings.
Hill-Rom Advanta 2
Power Cord Replacement
Perform an electrical safety test on a Hill Rom patient bed using a BC Group SA-2005 safety analyzer. Determine that the power cord is faulty and replace it.
Ranger 245 Fluid Warmer
Preventative Maintenance
Complete Preventative Maintenance procedures on the 3M Ranger 245 Fluid Warmer with fuse replacement.
SSCOR Duet 2314 Portable Suction Regulator
PMI with Battery Replacement
Perform a complete preventative Maintenance procedure on the SSCOR portable suction regulator using an airflow meter. Test and replace the internal battery as required by the procedure.
MEDRAD Stellant Dual Head CT Contrast Injector
Preventative Maintenance (1 of 4)
For part one of the complete preventive maintenance modules, complete the cleaning, teardown, and visual inspection portions of the PM. Replace gaskets and worn parts as required.
Philips Epiq 7 Ultrasound System
Component Replacements
Perform a full teardown of the Philips Epiq 7 with detailed guides for component replacement procedures, including battery and power supplies, E-Box, Display Monitor, and Control Panel Assembly.
Electrical Safety Analyzers
Electrical Safety Test
Perform an electrical safety test on a Welch Allyn patient monitor using three different electrical safety analyzers.
Ritter UltraClave Tabletop Sterilizer
Preventative Maintenance
Preventative Maintenance inspection on the Midmark / Ritter M9 Ultraclave tabletop sterilizer.
GE AMX 4 Portable X-Ray
Battery Replacement
Complete all necessary procedures to remove and replace all 9 DC batteries within the unit. Use a multimeter to verify that the new batteries are providing the proper power levels to the unit.
Valleylab FT10 ESU
Preventative Maintenance
Complete the preventative maintenance inspection procedures on an electrosurgical unit using a BC Group ESU-2300 ESU analyzer.
Zoll R Series Defibrillator
Preventative Maintenance
Full preventative maintenance procedures for a Zoll R Series defibrillator using a Fluke Impulse 7000DP analyzer.
BD Alaris IV Pump
Output Test
Complete flow, rate, and output tests for an Alaris 8100 infusion pump. Use the Pronk Flowtrax to perform a pressure test.
Siemens Definition AS CT Scanner Straton MX-P
X-Ray Tube Replacement
Complete X-ray tube uninstall procedures in this single tube CT scanner. Then complete the install procedures for a new Straton MX-P X-ray tube.